SPECIFICATION:
Type |
Wall Mounted |
Unit |
Air Conditioner |
Indoor Unit |
CS-KS18NKU |
Outdoor Unit |
CU-KS18NKU |
Performance & Electrical Ratings |
|
Capacity Cooling (Btu/h) |
17,500 (4,000-17,500) |
Capacity Heating (Btu/h) |
|
Moisture Removal - High - Pints/H |
4.89 |
Dry Air Flow - High -CFM |
524 |
Dry Air Flow - Medium -CFM |
441 |
Dry Air Flow - Low -CFM |
377 |
SEER - Cooling |
20 |
EER - Cooling |
11.7 |
HSPF - Heating |
|
Power Supply V, Phase, Hz |
230/208V, 1PH, 60Hz |
Running Amps - Cooling - A |
7 / 7.7(1.2~7.7) |
Running Amps - Heating - A |
|
Power Input - Cooling - W |
1,500 / 1,500(250~1,500) |
Power Input - Heating - W |
|
Back-up Heater kW |
|
Fuse or Circuit Breaker Capacity - A |
15 |
Features |
|
Controls |
Microprocessor |
Low Ambient Control |
Equipped |
Wireless Remote Controller |
Included |
Wired Remote Controller (optional) |
CZ-RD515U & CZ-RC515U |
Fan Speeds |
Hi / Me / Lo & Auto |
Timer |
1hr OFF and 24-hr Program |
Air Deflection - Horizontal |
Manual |
Air Deflection - Vertical |
Automatic |
Air Filter |
Washable |
Refrigerant |
R-410A |
Refrigerant Control |
Electric Expansion Valve |
Operation Sound - In(Hi / Me / Lo/ Qt) dB-A |
42 / 38 / 30 / 28 |
Operation Sound - Outdoor (Hi) dB-A |
51 |
Refrigerant Piping -Type |
Flare |
Refrigerant Piping - Discharge - inches |
1/4" |
Refrigerant Piping - Suction - inches |
1/2" |
Refrigerant Pipe Length - ft |
Max. 100 |
Elevation Difference - Outdoor Above - ft |
Max. 50 |
Elevation Difference - Outdoor Below - ft |
Max. 50 |
Dimensions & Weight |
|
Height (inches) |
Indoor Unit: 11-23/32" Outdoor Unit: 26-3/8" |
Width (inches) |
Indoor Unit: 41-15/16" Outdoor Unit: 34-21/32" |
Depth (inches) |
Indoor Unit: 8-19/32" Outdoor Unit: 11-7/32" |
Net Weight (lbs.) |
Indoor Unit: 26.5 Outdoor Unit: 90.4 |
DESCRIPTION:
Panasonic’s Ductless Split Air Conditioner products offer wide versatility in solving your cooling for a single. The Indoor unit(evaporator) is mounted inside the room, enclosed in a handsome space saving cabinet. It is connected to the outdoor unit(condenser) via refrigerant lines & inter-unit wiring through a 3-1/2” opening in the wall. Since no ductwork is required, installation is simple, fast & efficient. The indoor unit has been uniquely designed to provide Whisper Quiet operation while delivering comfort throughout the room(s). Panasonic Ductless Split Systems bring together sleek styling in wall, duct or ceiling mounted systems, with whisper quiet operations, quality & reliability you can count on.
Microprocessor-Controlled Operation
Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable.
Wireless Remote Control
Panasonic’s infrared Remote Control with and easy to read LCD Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer and more, for complete automatic operation.
Self-Diagnosing Function
Details of previous warnings are stored and can be verified on the liquid crystal display. This makes it easier to diagnose malfunctions, greatly reducing service labor. (Wired remote controller)
Dry Mode
By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified.
3 Fan Speeds and Automatic Fan Operation
Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. According to room temperature to maintain a comfortable airflow throughout the room.
Air Sweep Control
The air sweep function moves the louver up and down in the air outlet, directing air in a “sweeping” motion around the room and providing comfort in every corner.
Louver Control
Louver can be manually set to the desired angle by remote control.
Night Setback Mode for Cooling and Heating
Cooling and DRY Mode:
With the Night Setback Mode, the air conditioner automatically raises the setting temperature 2°F after 30 minutes, and then another 2°F after the next 30 minutes.
Heating Mode:
With the Night Setback Mode, the setting temperature is automatically lowered 4°F after 30 minutes, and then another 4°F after the next 30 minutes. This saves energy without sacrificing comfort and is ideal for gentle cooling and heating.
24-hour Clock with ON/OFF Program Timer
The remote control unit allows you to set a wide variety of timer-based operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer.
1-hour OFF Timer
When this button is pushed either while the unit is operating or while it is stopped, the unit will operate for one hour and then switch off automatically.
Automatic Restart Function after Power Failure
This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure.
Electric Refrigerant Control Valve
The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps.
R-410A
A proven blend of refrigerant with a low ozone depleting potential.
Quiet Mode
LOW, low fan speed for extra quiet operation.